06/26/2026, 3:52 PMretrying or running for 7 days, when I checked the web dashboard I saw that it triggered for no reason 3 times, the flow runs that caused that lasted a few seconds only (instead of 7 days)Marvin
06/26/2026, 3:52 PMMarvin
06/26/2026, 3:54 PMrunning or retrying for 7 days” — the trigger logic is basically:
- see a Running or Retrying event
- wait 7 days
- if no matching terminal event is seen in that window, fire the automation
So if the UI later shows that run only lasted a few seconds, that usually suggests one of these:
1. The automation saw an event sequence that was incomplete or delayed
- e.g. it saw Running, but the terminal event it expected wasn’t available in time for evaluation
2. The trigger is matching a run/event you’re not interpreting the same way from the UI
- sometimes the “causing” run in the dashboard is confusing unless you inspect the exact event trail
3. There may be an event-ordering / timestamp discrepancy
- Prefect automations rely on event timing and processing, not just the final rendered duration in the UI
A few important details:
- Retrying is a state name under a running-type state, so transitions through retry logic can create separate events.
- Proactive automations like this one fire based on the absence of expected events over time.
- Prefect’s event system has ordering/buffering logic, so under some conditions an automation can appear to fire “for no reason” if the relevant terminal event wasn’t considered in the right window.
Relevant docs:
- Event triggers
- Flow run events
- Detect zombie flows — this is related because it uses the same proactive “missing event within time window” pattern
What I’d recommend checking next:
1. Open one of the triggered automation executions and inspect:
- the triggering event type
- the occurred timestamp
- the resource id / flow run id
2. Compare that to the flow run’s state history
- was there definitely a Completed, Failed, Crashed, or Cancelled state after the `Running`/`Retrying` event?
3. Check whether the run was resubmitted / retried / recreated
- sometimes multiple state transitions for the same run make this less obvious
4. If possible, look at the raw events for that flow run rather than only the duration shown in the run UI
If you want, I can help you narrow this down. If you paste:
- the automation trigger configuration
- one example flow run id
- what terminal state that run ended in
I can help you reason through whether this looks like expected event semantics, misconfiguration, or a possible bug.
If it does look like a bug, the best public contact paths are:
- GitHub issues: prefect issues
- Community discussion: prefect discussionsMarvin
06/26/2026, 4:00 PMMarvin
06/26/2026, 4:00 PM2026-06-26T02:10:31.106Z
- because it saw a prefect.flow-run.Running event at 2026-06-19T02:10:31.042899Z
- for flow run prefect.flow-run.06a34a4e-73a2-7e31-8000-2207ced6cd2d
That is almost exactly 7 days later, so the automation engine behaved consistently with a proactive “still running after 7 days” rule.
The key thing missing from this payload is:
there is no evidence here that the automation ever saw a terminal event for that same flow run.
That’s the whole story.
If the run truly finished in ~7 seconds, then for this automation not to fire, Prefect would have needed to observe a later event for the same prefect.resource.id such as one of:
- prefect.flow-run.Completed
- prefect.flow-run.Failed
- prefect.flow-run.Crashed
- prefect.flow-run.Cancelled
before 2026-06-26T02:10:31.042899Z.
From the body you pasted, we can infer a few concrete things:
1. The trigger was keyed by the flow run id
"triggering_labels": {
"prefect.resource.id": "prefect.flow-run.06a34a4e-73a2-7e31-8000-2207ced6cd2d"
}
So this wasn’t some unrelated run accidentally attached in the UI. It was definitely watching that exact run.
2. The triggering event was the transition into Running
"event": "prefect.flow-run.Running"
"prefect.state-timestamp": "2026-06-19T02:10:31.042899+00:00"
So the automation’s 7-day timer started there.
3. The event was received normally
"received": "2026-06-19T02:10:31.146845Z"
Only ~100ms after occurred, so this does not look like a delayed-arrival problem for the Running event.
4. The run sat in Pending for ~47 seconds before Running
- `Pending`: 02:09:43.693502
- `Running`: 02:10:31.042899
That’s interesting operationally, but not relevant to the false trigger by itself.
So the concrete conclusion is:
This automation fired because, from the event system’s perspective, that flow run entered Running and no qualifying terminal flow-run event cancelled the 7-day watch.
That leaves a few plausible explanations:
Most likely explanation: the run UI and the event stream disagreed for that run
- The run may show as having completed in a few seconds
- but the matching `Completed`/`Failed`/etc event may never have been emitted, ingested, or associated properly for automations
Other plausible explanation: your automation’s expected “ending states” don’t include the actual terminal state/event
- If the automation was configured through the UI, this is less likely, but still possible depending on the exact rule
- For example, if the run ended in a state/event that your trigger does not treat as resolving the watch, it would still fire
Less likely from this payload: clock skew or late processing of the Running event
- the Running event timing looks normal
What I’d check next, very specifically:
For this exact flow run id 06a34a4e-73a2-7e31-8000-2207ced6cd2d, find whether there exists a terminal event with the same prefect.resource.id.
You want to see one of these after `2026-06-19T021031.042899Z`:
- prefect.flow-run.Completed
- prefect.flow-run.Failed
- prefect.flow-run.Crashed
- prefect.flow-run.Cancelled
If you can inspect the run’s event history and you do not see one of those, then the automation is behaving correctly and the issue is really:
“why did this flow run appear to finish in the UI without a terminal flow-run event?”
If you do see one of those events for the same run id before the 7-day deadline, then this starts to look like a real automation bug.
One more subtle thing I notice:
The automation event references the triggering event as:
"related": [
{
"prefect.resource.id": "prefect-cloud.event.06a34a51-70af-798d-8000-bd77afb1e738",
"prefect.resource.role": "triggering-event"
}
]Marvin
06/26/2026, 4:00 PMRunning for that run, and apparently did not see a terminal event that would close the proactive trigger window.
If you want, send me either:
- the event/history list for that same run id, or
- a screenshot/copy of the run’s state timeline
and I can help determine whether this is:
- missing terminal event ingestion,
- a mismatch between UI state history and automation events,